The LU201 Illuminance Detector can continuously monitor the environmental illuminance inside the cover, and convert the measured value into a linear proportional signal output. The instrument uses a high-precision silicon photocell as the sensing element. The optical signal is converted into an electrical signal by a professionally designed cosine corrector and a special high-efficiency filter to the sensing element, and then processed by a highly integrated circuit to output a continuous linear proportional signal.
Technical Index:
Measuring Range: 0~20000Lx (O~6500cd/m2) can be specified when ordering
Measurement Accuracy: ≤±0.lLx or ±O.lcd/m2
Power Supply: AClOO~250V 50 Hz 10W+20W (heating)
Load Impedance: 1000Ω
Repeatability of Indication: ≤±0.1%
Spectral Response Error: ≤±1%
UV Response Error: ≤±1%
Indication Error: ≤±1%
Infrared Response Error: ≤±1%
Working Temperature: -50~75℃
Working Humidity: 0%~100%
Output Signal Protection: 24V
Protection Level: IP67
Weight: about 2 Kg
Signal Output:
Switch Output: 3 groups of relay contacts
Analog Output: 4/0~20mA is proportional to O~20000Lx (O~6500cd/m2)
Digital Output: RS232/RS422/RS485